小狗阅读会员会员
医学顶刊SCI精读工具

扫码登录小狗阅读

阅读SCI医学文献
Document
订阅泛读方向 订阅泛读期刊
  • 我的关注
  • 我的关注
  • {{item.title}}

    按需关注领域/方向,精准获取前沿热点

  • {{item.title}}

    {{item.follow}}人关注

  • {{item.subscribe_count}}人订阅

    IF:{{item.impact_factor}}

    {{item.title}}

Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study.

全身麻醉期间患者特异性生物力学模型增强的心血管生理监测。概念研究的证明。

  • 影响因子:3.02
  • DOI:10.1371/journal.pone.0232830
  • 作者列表:"Le Gall A","Vallée F","Pushparajah K","Hussain T","Mebazaa A","Chapelle D","Gayat É","Chabiniok R
  • 发表时间:2020-05-14
Abstract

:During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (Vva), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased Vva (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, Vva increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.

摘要

: 在全身麻醉 (GA) 期间,动脉压或主动脉血流波形的直接分析在复杂情况下可能是不确定的。基于在GA期间获得的数据并且能够执行心动周期的快速模拟的患者特异性生物力学模型具有增强血液动力学监测的潜力。这样的模型允许模拟压力-体积 (PV) 环路并估计心血管 (CV) 系统的功能指标,例如心室-动脉耦合 (Vva) 、心脏效率 (CE) 或心肌收缩性,在整个GA中演变。在这项前瞻性观察性研究中,我们为n = 45例接受GA的患者创建了心脏和脉管系统的患者特异性生物力学模型,降低了几何复杂度,同时使用经胸超声心动图和在GA开始时采集的主动脉压力和血流信号 (基线条件)。如果出现术中低血压 (IOH),则给予稀释的去甲肾上腺素 (NOR),并根据测量的主动脉压力和血流信号重新调整模型。这些患者被事后分配到所谓的低血压组。在所有患者中,模拟平均主动脉压 (MAP) 和每搏输出量 (SV) 在基线时的准确性符合新设备验证指南或参考测量方法。在低血压组中给予NOR后,对于MAP和SV,在测量和模拟之间具有10% 排除区域的一致性百分比均> 95%。建模结果显示,与血压正常患者相比,低血压患者的Vva降低 (0.64 ± 0.37 vs 0.88 ± 0.43; p = 0.039),CE增加 (0.8 ± 0.1 vs 0.73 ± 0.11; p = 0.042)。此外,在低血压组中,Vva增加92 ± 101%,CE减少13 ± 11% (两者均p <0.001),收缩性增加14 ± 11% (p = 0.002)。在这项工作中,我们展示了快速运行的患者特异性生物物理模型的应用,以使用GA期间可用的临床数据来估计CV系统的PV回路和功能指标。这项工作为手术室或重症监护病房的模型增强血流动力学监测铺平了道路,以增强患者特定生理信息。

关键词:
阅读人数:14人
下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:2.27
发表时间:2020-02-01
DOI:10.1213/ANE.0000000000003945
作者列表:["Winterberg AV","Ding L","Hill LM","Stubbeman BL","Varughese AM"]

METHODS:BACKGROUND:Anxiety and distress behaviors during anesthesia induction are associated with negative postoperative outcomes for pediatric patients. Documenting behavioral responses to induction is useful to evaluate induction quality at hospitals and to optimize future anesthetics for returning patients, but we lack a simple tool for clinical documentation. The Induction Compliance Checklist is a tool for grading induction behaviors that is well validated for research purposes, but it is not practical for routine documentation in busy clinical practice settings. The Child Induction Behavioral Assessment tool was developed to provide a simple and easy to use electronic tool for clinical documentation of induction behaviors. The aim of this study was to test the Child Induction Behavioral Assessment tool's concurrent validity with the Induction Compliance Checklist and the interrater reliability. METHODS:This prospective, observational study included 384 pediatric patients undergoing anesthesia inhalation induction. Concurrent validity with the Induction Compliance Checklist and interrater reliability of the Child Induction Behavioral Assessment were evaluated. Two researchers alternated scoring the Induction Compliance Checklist. The 2 researchers independently scored the Child Induction Behavioral Assessment. The anesthesia clinician caring for the patient also independently scored the Child Induction Behavioral Assessment by completing their routine documentation in the patient's medical record. Two age groups were evaluated (ages 1-3 and 4-12 years old). RESULTS:Clinicians' and researchers' Child Induction Behavioral Assessment scores demonstrated a strong correlation with the Induction Compliance Checklist (P < .0001). There was an excellent agreement between the 2 researchers' Child Induction Behavioral Assessment scores for the younger and older age groups, respectively (Kappa [95% CI] = 0.97 (0.94-0.99); K = 0.94 (0.89-0.99)]. The agreement between the researchers and the 117 clinicians who documented Child Induction Behavioral Assessment assessments in the medical record was good overall (intraclass correlation coefficient = 0.70), with fair agreement with the 1- to 3-year-old patients (intraclass correlation coefficient = 0.56) and good agreement for the 4- to 12-year-old patients (intraclass correlation coefficient = 0.74). CONCLUSIONS:The Child Induction Behavioral Assessment scale is a simple and practical electronic tool used to document pediatric behavioral responses to anesthesia inductions. This study provides evidence of the tool's validity and reliability for inhalation inductions. Future research is needed at other hospitals to confirm validity.

关键词: 暂无
翻译标题与摘要 下载文献
影响因子:2.27
发表时间:2020-01-01
DOI:10.1213/ANE.0000000000003975
作者列表:["Uppal V","Retter S","Casey M","Sancheti S","Matheson K","McKeen DM"]

METHODS:BACKGROUND:Fentanyl and morphine are the 2 most commonly added opioids to bupivacaine for spinal anesthesia during cesarean delivery. Numerous clinical trials have assessed efficacy and safety of different doses of fentanyl added to intrathecal bupivacaine for spinal anesthesia, yet its benefit, harm, and optimal dose remain unclear. This study aimed to systematically review the evidence of the efficacy of fentanyl when added to intrathecal bupivacaine alone and when added to bupivacaine with morphine for spinal anesthesia during cesarean delivery. METHODS:Key electronic databases (PubMed, Embase, and Cochrane Library) were searched for randomized controlled trials in the cesarean delivery population. The primary outcome was the failure rate of spinal anesthesia, as assessed by the need for either conversion to general anesthesia or intraoperative analgesic supplementation. Two reviewers independently extracted the data using a standardized electronic form. Results are expressed as relative risks or mean differences with 95% CIs. RESULTS:Seventeen randomized controlled clinical trials (most judged as low or unclear risk of bias) with 1064 participants provided data for the meta-analysis. Fentanyl added to intrathecal bupivacaine alone reduced the need for intraoperative supplemental analgesia (relative risk, 0.18; 95% CI, 0.11-0.27; number needed to treat, 4) and the incidence of nausea/vomiting (relative risk, 0.41; 95% CI, 0.24-0.70; number needed to treat, 6.5), with longer time to first postoperative analgesia request (mean difference, 91 minutes; 95% CI, 69-113). No difference was observed regarding the need for conversion to general anesthesia (relative risk, 0.67; 95% CI, 0.12-3.57), the incidence of hypotension, the onset of sensory block, or the duration of motor block. However, the addition of intrathecal fentanyl was associated with higher incidence of intraoperative pruritus (relative risk, 5.89; 95% CI, 2.07-16.79; number needed to harm, 13.5). The inclusion of fentanyl to intrathecal bupivacaine-morphine compared to intrathecal bupivacaine-morphine alone conferred a similar benefit, with a significantly reduced need for intraoperative supplemental analgesia (relative risk, 0.16; 95% CI, 0.03-0.95; number needed to treat, 9). Analysis using a funnel plot indicated a possibility of publication bias in included studies. CONCLUSIONS:Current evidence suggests a benefit of using fentanyl as both an additive to intrathecal bupivacaine alone and to intrathecal bupivacaine combined with morphine for cesarean delivery under spinal anesthesia. The possibility of publication bias, small sample size, and high risk of bias in some of the included studies warrant treating the results with caution.

关键词: 暂无
翻译标题与摘要 下载文献
影响因子:2.27
发表时间:2020-05-01
DOI:10.1213/ANE.0000000000004012
作者列表:["Jean YK","Kam D","Gayer S","Palte HD","Stein ALS"]

METHODS::Ophthalmic pediatric regional anesthesia has been widely described, but infrequently used. This review summarizes the available evidence supporting the use of conduction anesthesia in pediatric ophthalmic surgery. Key anatomic differences in axial length, intraocular pressure, and available orbital space between young children and adults impact conduct of ophthalmic regional anesthesia. The eye is near adult size at birth and completes its growth rapidly while the orbit does not. This results in significantly diminished extraocular orbital volumes for local anesthetic deposition. Needle-based blocks are categorized by relation of the needle to the extraocular muscle cone (ie, intraconal or extraconal) and in the cannula-based block, by description of the potential space deep to the Tenon capsule. In children, blocks are placed after induction of anesthesia by a pediatric anesthesiologist or ophthalmologist, via anatomic landmarks or under ultrasonography. Ocular conduction anesthesia confers several advantages for eye surgery including analgesia, akinesia, ablation of the oculocardiac reflex, and reduction of postoperative nausea and vomiting. Short (16 mm), blunt-tip needles are preferred because of altered globe-to-orbit ratios in children. Soft-tip cannulae of varying length have been demonstrated as safe in sub-Tenon blockade. Ultrasound technology facilitates direct, real-time visualization of needle position and local anesthetic spread and reduces inadvertent intraconal needle placement. The developing eye is vulnerable to thermal and mechanical insults, so ocular-rated transducers are mandated. The adjuvant hyaluronidase improves ocular akinesia, decreases local anesthetic dosage requirements, and improves initial block success; meanwhile, dexmedetomidine increases local anesthetic potency and prolongs duration of analgesia without an increase in adverse events. Intraconal blockade is a relative contraindication in neonates and infants, retinoblastoma surgery, and in the presence of posterior staphylomas and buphthalmos. Specific considerations include pertinent pediatric ophthalmologic topics, block placement in the syndromic child, and potential adverse effects associated with each technique. Recommendations based on our experience at a busy academic ophthalmologic tertiary referral center are provided.

关键词: 暂无
翻译标题与摘要 下载文献
麻醉方向

用药物或其他方法使患者整体或局部暂时失去感觉,以达到无痛的目的进行手术治疗。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

科研福利

临床科研之家订阅号

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: