小狗阅读会员会员
医学顶刊SCI精读工具

扫码登录小狗阅读

阅读SCI医学文献
Document
订阅泛读方向 订阅泛读期刊
  • 我的关注
  • 我的关注
  • {{item.title}}

    按需关注领域/方向,精准获取前沿热点

  • {{item.title}}

    {{item.follow}}人关注

  • {{item.subscribe_count}}人订阅

    IF:{{item.impact_factor}}

    {{item.title}}

3D visualization ablation planning system assisted microwave ablation for hepatocellular carcinoma (Diameter >3): a precise clinical application.

三维可视化消融规划系统辅助微波消融治疗肝细胞癌 (直径> 3): 精确的临床应用。

  • 影响因子:3.29
  • DOI:10.1186/s12885-020-6519-y
  • 作者列表:"An C","Li X","Zhang M","Yang J","Cheng Z","Yu X","Han Z","Liu F","Dong L","Yu J","Liang P
  • 发表时间:2020-01-20
Abstract

BACKGROUND:The aim of this retrospective study was to compare the feasibility and efficiency of ultrasound-guided percutaneous microwave ablation (US-PMWA) assisted by three-dimensional visualization ablation planning system (3DVAPS) and conventional 2D planning for hepatocellular carcinoma (HCC) (diameter > 3 cm). METHODS:One hundred thirty patients with 223 HCC nodules (5.0 ± 1.5 cm in diameter, [3.0-10.0 cm]) who met the eligibility criteria divided into 3D and 2D planning group were reviewed from April 2015 to August 2018. Ablation parameters and oncological outcomes were compared, including overall survival (OS), recurrence-free survival (RFS), and local tumor progression (LTP). Multivariate analysis was performed on clinicopathological variables to identify the risk factors for OS and LTP. RESULTS:The median follow-up period was 21 months (range 3-44). Insertion number (5.4 ± 1.2 VS. 4.5 ± 0.9, P = 0.034), ablation time (1249.2 ± 654.2 s VS. 1082.4 ± 584.7 s, P = 0.048), ablation energy (57,000 ± 11,892 J VS. 42,600 ± 10,271 J, P = 0.038) and success rate of first ablation (95.0% VS. 85.7%, P = 0.033) were higher in the 3D planning group compared with those in 2D planning group. There was no statistical difference in OS, and RFS between the two groups (P = 0.995, P = 0.845). LTP rate of 3D planning group was less than that of 2D planning group (16.5% VS 41.2%, P = 0.003). Multivariate analysis showed tumor maximal diameters (P < 0.001), tumor number (P = 0.003) and preoperative TACE (P < 0.001) were predictors for OS and sessions (P = 0.024), a-fetoprotein level (P = 0.004), and preoperative planning (P = 0.002) were predictors for LTP, respectively. CONCLUSIONS:3DVAPS improves precision of US guided ablation resulting in lower LTP and higher 5 mm-AM for patients with HCC lesions larger than 3 cm in diameter.

摘要

背景: 这项回顾性研究的目的是比较超声引导下三维可视化消融计划系统 (3DVAPS) 辅助的经皮微波消融 (us-pmwa) 和传统的肝细胞癌 (HCC) 二维规划 (直径> 3  cm) 的可行性和效率。 方法: 回顾2015年4月至2018年8月符合入选标准的223例HCC结节 (直径5.0 ± 1.5 cm,[3.0-10.0 cm]) 患者,分为3D和2D规划组。比较消融参数和肿瘤学结果,包括总生存期 (OS),无复发生存期 (RFS) 和局部肿瘤进展 (LTP)。对临床病理变量进行多变量分析以确定OS和LTP的风险因素。 结果: 中位随访时间为21个月 (范围3-44)。插入数 (5.4 ± 1.2 VS.4.5 ± 0.9,p   =   0.034),消融时间 (1249.2 ± 654.2  s VS.1082.4 ± 584.7 s s,p   = 0.048 57,000),消融能量 (11,892 ± j j VS.42,600 ± 10,271 j j,p   = 0.038 95.0%) 和首次消融成功率 (VS.85.7%,p   = 0.033) 3D规划组高于2D规划组。两组间OS、RFS差异无统计学意义 (p = 0.995,p = 0.845)。3D规划组LTP率低于2D规划组 (16.5% VS 41.2%,p   =   0.003)。多因素分析显示肿瘤最大直径 (P <0.001) 、肿瘤数目 (P = 0.003) 和术前TACE (P <0.001) 是OS和sessions (P = 0.024) 、甲胎蛋白水平 (P = 0.004) 、术前计划 (p = 0.002) 分别是LTP的预测因子。 结论: 3DVAPS提高了超声引导下消融的精确度,对于直径大于3 cm的HCC患者,LTP更低,5mm-AM更高。

下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:4.08
发表时间:2020-01-01
来源期刊:European radiology
DOI:10.1007/s00330-019-06319-0
作者列表:["Delattre BMA","Boudabbous S","Hansen C","Neroladaki A","Hachulla AL","Vargas MI"]

METHODS:OBJECTIVES:The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS:CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS:No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS:The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS:• Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.

翻译标题与摘要 下载文献
影响因子:2.98
发表时间:2020-01-01
DOI:10.1136/neurintsurg-2019-014962
作者列表:["Guo W","Liu H","Tan Z","Zhang X","Gao J","Zhang L","Guo H","Bai H","Cui W","Liu X","Wu X","Luo J","Qu Y"]

METHODS:BACKGROUND:The main surgical techniques for spontaneous basal ganglia hemorrhage include stereotactic aspiration, endoscopic aspiration, and craniotomy. However, credible evidence is still needed to validate the effect of these techniques. OBJECTIVE:To explore the long-term outcomes of the three surgical techniques in the treatment of spontaneous basal ganglia hemorrhage. METHODS:Five hundred and sixteen patients with spontaneous basal ganglia hemorrhage who received stereotactic aspiration, endoscopic aspiration, or craniotomy were reviewed retrospectively. Six-month mortality and the modified Rankin Scale score were the primary and secondary outcomes, respectively. A multivariate logistic regression model was used to assess the effects of different surgical techniques on patient outcomes. RESULTS:For the entire cohort, the 6-month mortality in the endoscopic aspiration group was significantly lower than that in the stereotactic aspiration group (odds ratio (OR) 4.280, 95% CI 2.186 to 8.380); the 6-month mortality in the endoscopic aspiration group was lower than that in the craniotomy group, but the difference was not significant (OR=1.930, 95% CI 0.835 to 4.465). A further subgroup analysis was stratified by hematoma volume. The mortality in the endoscopic aspiration group was significantly lower than in the stereotactic aspiration group in the medium (≥40-<80 mL) (OR=2.438, 95% CI 1.101 to 5.402) and large hematoma subgroup (≥80 mL) (OR=66.532, 95% CI 6.345 to 697.675). Compared with the endoscopic aspiration group, a trend towards increased mortality was observed in the large hematoma subgroup of the craniotomy group (OR=8.721, 95% CI 0.933 to 81.551). CONCLUSION:Endoscopic aspiration can decrease the 6-month mortality of spontaneous basal ganglia hemorrhage, especially in patients with a hematoma volume ≥40 mL.

影响因子:0.96
发表时间:2020-02-01
DOI:10.1002/jcu.22762
作者列表:["Meng L","Zhao D","Yang Z","Wang B"]

METHODS:OBJECTIVE:The primary purpose of this study was to evaluate the effectiveness of a three-dimensional (3D) software tool (smart planes) for displaying fetal brain planes, and the secondary purpose was to evaluate its accuracy in performing automatic measurements. MATERIAL AND METHODS:This prospective study included singleton fetuses with a gestational age (GA) greater than 18 weeks. Transabdominal two-dimensional ultrasound (2DUS) and 3D smart planes images were respectively used to obtain the basic planes of the fetal brain, with five parameters measured. The images, by either two-dimensional (2D) manual or 3D automatic operation, were reviewed by two experienced sonographers. The agreements between two measurements were analyzed. RESULTS:A total of 226 cases were included. The rates of successful detection by automatic display were as high as 80%. There was substantial agreement between the measurements of the biparietal diameter, head circumference and transcerebellar diameter, but poor agreement between the measurements of cisterna magna and lateral ventricle width. CONCLUSIONS:Smart Planes might be valuable for the rapid evaluation of fetal brain, because it simplifies the evaluation process. However, the technology requires improvement. In addition, this technology cannot replace the conventional manual US scans; it can only be used as an additional approach.

翻译标题与摘要 下载文献
三维成像方向

用电子、摄影或其他方法产生三维图像的过程。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: