4D-CT angiography versus 3D-rotational angiography as the imaging modality for computational fluid dynamics of cerebral aneurysms.

4D-CT血管造影与3d旋转血管造影作为脑动脉瘤计算流体动力学的成像方式。

  • 影响因子:2.98
  • DOI:10.1136/neurintsurg-2019-015389
  • 作者列表:"Cancelliere NM","Najafi M","Brina O","Bouillot P","Vargas MI","Lovblad KO","Krings T","Pereira VM","Steinman DA
  • 发表时间:2020-06-01
Abstract

BACKGROUND AND PURPOSE:Computational fluid dynamics (CFD) can provide valuable information regarding intracranial hemodynamics. Patient-specific models can be segmented from various imaging modalities, which may influence the geometric output and thus hemodynamic results. This study aims to compare CFD results from aneurysm models segmented from three-dimensional rotational angiography (3D-RA) versus novel four-dimensional CT angiography (4D-CTA). METHODS:Fourteen patients with 16 cerebral aneurysms underwent novel 4D-CTA followed by 3D-RA. Endoluminal geometries were segmented from each modality using an identical workflow, blinded to the other modality, to produce 28 'original' models. Each was then minimally edited a second time to match length of branches, producing 28 additional 'matched' models. CFD simulations were performed using estimated flow rates for 'original' models (representing real-world experience) and patient-specific flow rates from 4D-CTA for 'matched' models (to control for influence of modality alone). RESULTS:Overall, geometric and hemodynamic results were consistent between models segmented from 3D-RA and 4D-CTA, with correlations improving after matching to control for operator-introduced variability. Despite smaller 4D-CTA parent artery diameters (3.49±0.97 mm vs 3.78±0.92 mm for 3D-RA; p=0.005) and sac volumes (157 (37-750 mm3) vs 173 (53-770 mm3) for 3D-RA; p=0.0002), sac averages of time-averaged wall shear stress (TAWSS), oscillatory shear (OSI), and high frequency fluctuations (measured by spectral power index, SPI) were well correlated between 3D-RA and 4D-CTA 'matched' control models (TAWSS, R2=0.91; OSI, R2=0.79; SPI, R2=0.90). CONCLUSIONS:Our study shows that CFD performed using 4D-CTA models produces reliable geometric and hemodynamic information in the intracranial circulation. 4D-CTA may be considered as a follow-up imaging tool for hemodynamic assessment of cerebral aneurysms.

摘要

背景和目的: 计算流体动力学 (CFD) 可以提供有关颅内血流动力学的有价值的信息。可以从各种成像模式中分割患者特异性模型,其可以影响几何输出并因此影响血液动力学结果。本研究旨在比较三维旋转血管造影 (3D-RA) 与新型四维CT血管造影 (4D-CTA) 分割的动脉瘤模型的CFD结果。 方法: 14例16个脑动脉瘤患者接受新型4D-CTA和3D-RA。使用相同的工作流程从每种模态中分割腔内几何形状,对另一种模态进行盲法,以产生28个 “原始” 模型。然后第二次对每个进行最低限度的编辑以匹配分支的长度,产生28个额外的 “匹配” 模型。使用 “原始” 模型 (代表真实世界经验) 的估计流速和来自 “匹配” 模型的4D-CTA的患者特定流速进行CFD模拟 (以单独控制模态的影响)。 结果: 从3D-RA和4D-CTA分割的模型之间的总体、几何和血流动力学结果是一致的,在与操作者引入的变异性的对照匹配后,相关性得到改善。尽管4D-CTA母动脉直径较小 (3.49 ± 0.97mm vs 3.78 ± 0.92mm,对于3D-RA; p = 0.005) 和sac体积 (157 (37-750立方毫米) vs 173 (53-770立方毫米),对于3D-RA; p = 0.0002),时间平均壁面剪切应力 (TAWSS) 、振荡剪切 (OSI) 和高频波动的sac平均值(通过光谱功率指数测量,SPI) 在3D-RA和4D-CTA “匹配” 对照模型之间具有良好的相关性 (TAWSS,R2 = 0.91; OSI,R2 = 0.79; SPI,R2 = 0.90)。 结论: 我们的研究表明,使用4D-CTA模型进行的CFD在颅内循环中产生可靠的几何和血液动力学信息。4D-CTA可作为脑动脉瘤血流动力学评估的后续成像工具。

下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:4.08
发表时间:2020-01-01
来源期刊:European radiology
DOI:10.1007/s00330-019-06319-0
作者列表:["Delattre BMA","Boudabbous S","Hansen C","Neroladaki A","Hachulla AL","Vargas MI"]

METHODS:OBJECTIVES:The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS:CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS:No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS:The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS:• Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.

翻译标题与摘要 下载文献
影响因子:2.98
发表时间:2020-01-01
DOI:10.1136/neurintsurg-2019-014962
作者列表:["Guo W","Liu H","Tan Z","Zhang X","Gao J","Zhang L","Guo H","Bai H","Cui W","Liu X","Wu X","Luo J","Qu Y"]

METHODS:BACKGROUND:The main surgical techniques for spontaneous basal ganglia hemorrhage include stereotactic aspiration, endoscopic aspiration, and craniotomy. However, credible evidence is still needed to validate the effect of these techniques. OBJECTIVE:To explore the long-term outcomes of the three surgical techniques in the treatment of spontaneous basal ganglia hemorrhage. METHODS:Five hundred and sixteen patients with spontaneous basal ganglia hemorrhage who received stereotactic aspiration, endoscopic aspiration, or craniotomy were reviewed retrospectively. Six-month mortality and the modified Rankin Scale score were the primary and secondary outcomes, respectively. A multivariate logistic regression model was used to assess the effects of different surgical techniques on patient outcomes. RESULTS:For the entire cohort, the 6-month mortality in the endoscopic aspiration group was significantly lower than that in the stereotactic aspiration group (odds ratio (OR) 4.280, 95% CI 2.186 to 8.380); the 6-month mortality in the endoscopic aspiration group was lower than that in the craniotomy group, but the difference was not significant (OR=1.930, 95% CI 0.835 to 4.465). A further subgroup analysis was stratified by hematoma volume. The mortality in the endoscopic aspiration group was significantly lower than in the stereotactic aspiration group in the medium (≥40-<80 mL) (OR=2.438, 95% CI 1.101 to 5.402) and large hematoma subgroup (≥80 mL) (OR=66.532, 95% CI 6.345 to 697.675). Compared with the endoscopic aspiration group, a trend towards increased mortality was observed in the large hematoma subgroup of the craniotomy group (OR=8.721, 95% CI 0.933 to 81.551). CONCLUSION:Endoscopic aspiration can decrease the 6-month mortality of spontaneous basal ganglia hemorrhage, especially in patients with a hematoma volume ≥40 mL.

影响因子:0.96
发表时间:2020-02-01
DOI:10.1002/jcu.22762
作者列表:["Meng L","Zhao D","Yang Z","Wang B"]

METHODS:OBJECTIVE:The primary purpose of this study was to evaluate the effectiveness of a three-dimensional (3D) software tool (smart planes) for displaying fetal brain planes, and the secondary purpose was to evaluate its accuracy in performing automatic measurements. MATERIAL AND METHODS:This prospective study included singleton fetuses with a gestational age (GA) greater than 18 weeks. Transabdominal two-dimensional ultrasound (2DUS) and 3D smart planes images were respectively used to obtain the basic planes of the fetal brain, with five parameters measured. The images, by either two-dimensional (2D) manual or 3D automatic operation, were reviewed by two experienced sonographers. The agreements between two measurements were analyzed. RESULTS:A total of 226 cases were included. The rates of successful detection by automatic display were as high as 80%. There was substantial agreement between the measurements of the biparietal diameter, head circumference and transcerebellar diameter, but poor agreement between the measurements of cisterna magna and lateral ventricle width. CONCLUSIONS:Smart Planes might be valuable for the rapid evaluation of fetal brain, because it simplifies the evaluation process. However, the technology requires improvement. In addition, this technology cannot replace the conventional manual US scans; it can only be used as an additional approach.

翻译标题与摘要 下载文献
三维成像方向

用电子、摄影或其他方法产生三维图像的过程。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

科研福利

临床科研之家订阅号

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: