小狗阅读会员会员
医学顶刊SCI精读工具

扫码登录小狗阅读

阅读SCI医学文献
Document
订阅泛读方向 订阅泛读期刊
  • 我的关注
  • 我的关注
  • {{item.title}}

    按需关注领域/方向,精准获取前沿热点

  • {{item.title}}

    {{item.follow}}人关注

  • {{item.subscribe_count}}人订阅

    IF:{{item.impact_factor}}

    {{item.title}}

Comparing the trueness of seven intraoral scanners and a physical impression on dentate human maxilla by a novel method.

用一种新方法比较了7个口内扫描仪和齿状上颌骨物理印模的真实性。

  • 影响因子:2.04800
  • DOI:10.1186/s12903-020-01090-x
  • 作者列表:"Nagy Z","Simon B","Mennito A","Evans Z","Renne W","Vág J
  • 发表时间:2020-04-07
Abstract

BACKGROUNDS:Intraoral scanner (IOS) accuracy is commonly evaluated using full-arch surface comparison, which fails to take into consideration the starting position of the scanning (scan origin). Previously a novel method was developed, which takes into account the scan origin and calculates the deviation of predefined identical points between references and test models. This method may reveal the error caused by stitching individual images during intraoral scan. This study aimed to validate the novel method by comparing the trueness of seven IOSs (Element 1, Element 2, Emerald, Omnicam, Planscan, Trios 3, CS 3600) to a physical impression digitized by laboratory scanner which lacks linear stitching problems. METHODS:Digital test models of a dentate human cadaver maxilla were made by IOSs and by laboratory scanner after polyvinylsiloxane impression. All scans started on the occlusal surface of the tooth #15 (universal notation, scan origin) and finished at tooth #2. The reference model and test models were superimposed at the scan origin in GOM Inspect software. Deviations were measured between identical points on three different axes, and the complex 3D deviation was calculated. The effect of scanners, tooth, and axis was statistically analyzed by the generalized linear mixed model. RESULTS:The deviation gradually increased as the distance from scan origin increased for the IOSs but not for the physical impression. The highest deviation occurred mostly at the apico-coronal axis for the IOSs. The mean deviation of the physical impression (53 ± 2 μm) was not significantly different from the Trios 3 (156 ± 8 μm) and CS 3600 (365 ± 29 μm), but it was significantly lower than the values of Element 1 (531 ± 26 μm), Element 2 (246 ± 11 μm), Emerald (317 ± 13 μm), Omnicam (174 ± 11 μm), Planscan (903 ± 49 μm). CONCLUSIONS:The physical impression was superior compared to the IOSs on dentate full-arch of human cadaver. The novel method could reveal the stitching error of IOSs, which may partly be caused by the difficulties in depth measurement.

摘要

背景: 口内扫描仪 (IOS) 精度通常使用全弓表面比较来评估,其没有考虑扫描的起始位置 (扫描原点)。以前开发了一种新的方法,其考虑扫描原点并计算参考和测试模型之间的预定义的相同点的偏差。该方法可以揭示在口内扫描期间由拼接单个图像引起的误差。本研究旨在通过比较七种IOSs (元素1,元素2,Emerald,Omnicam,Planscan,Trios 3,CS 3600) 与实验室扫描仪数字化的缺乏线性拼接问题的物理印象的真实性来验证新方法。 方法: 在聚乙烯基硅氧烷印模后,用IOSs和实验室扫描仪制作齿状人尸体上颌骨的数字测试模型。所有扫描在牙齿 #15的咬合表面上开始 (通用符号,扫描原点),并在牙齿 #2完成。参考模型和测试模型在GOM检查软件中的扫描原点处叠加。测量三个不同轴上的相同点之间的偏差,并计算复杂的3D偏差。通过广义线性混合模型统计分析扫描仪、牙齿和轴的影响。 结果: 随着距扫描原点的距离增加,IOSs的偏差逐渐增加,但物理印象没有增加。最高偏差主要发生在IOSs的apico-冠状轴。物理印象的平均偏差 (53 ± 2 ± μ m) 与Trios 3 (156 ± 8 ± μ m) 和CS 3600 (365 ± 29 ± μ m) 没有显著差异,但明显低于元素1 (531 ± 26 μ m) 、元素2 (246 ± 11 μ m) 、祖母绿 (317 ± 13 μ m) 、Omnicam (174 ± 11 μ m) 、planscan (903   ± 49 μm μm m)。 结论: 人尸体齿状全弓的物理印象优于IOSs。该方法可以揭示IOSs的拼接误差,这可能部分是由于深度测量困难造成的。

下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:4.08
发表时间:2020-01-01
来源期刊:European radiology
DOI:10.1007/s00330-019-06319-0
作者列表:["Delattre BMA","Boudabbous S","Hansen C","Neroladaki A","Hachulla AL","Vargas MI"]

METHODS:OBJECTIVES:The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS:CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS:No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS:The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS:• Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.

翻译标题与摘要 下载文献
影响因子:2.98
发表时间:2020-01-01
DOI:10.1136/neurintsurg-2019-014962
作者列表:["Guo W","Liu H","Tan Z","Zhang X","Gao J","Zhang L","Guo H","Bai H","Cui W","Liu X","Wu X","Luo J","Qu Y"]

METHODS:BACKGROUND:The main surgical techniques for spontaneous basal ganglia hemorrhage include stereotactic aspiration, endoscopic aspiration, and craniotomy. However, credible evidence is still needed to validate the effect of these techniques. OBJECTIVE:To explore the long-term outcomes of the three surgical techniques in the treatment of spontaneous basal ganglia hemorrhage. METHODS:Five hundred and sixteen patients with spontaneous basal ganglia hemorrhage who received stereotactic aspiration, endoscopic aspiration, or craniotomy were reviewed retrospectively. Six-month mortality and the modified Rankin Scale score were the primary and secondary outcomes, respectively. A multivariate logistic regression model was used to assess the effects of different surgical techniques on patient outcomes. RESULTS:For the entire cohort, the 6-month mortality in the endoscopic aspiration group was significantly lower than that in the stereotactic aspiration group (odds ratio (OR) 4.280, 95% CI 2.186 to 8.380); the 6-month mortality in the endoscopic aspiration group was lower than that in the craniotomy group, but the difference was not significant (OR=1.930, 95% CI 0.835 to 4.465). A further subgroup analysis was stratified by hematoma volume. The mortality in the endoscopic aspiration group was significantly lower than in the stereotactic aspiration group in the medium (≥40-<80 mL) (OR=2.438, 95% CI 1.101 to 5.402) and large hematoma subgroup (≥80 mL) (OR=66.532, 95% CI 6.345 to 697.675). Compared with the endoscopic aspiration group, a trend towards increased mortality was observed in the large hematoma subgroup of the craniotomy group (OR=8.721, 95% CI 0.933 to 81.551). CONCLUSION:Endoscopic aspiration can decrease the 6-month mortality of spontaneous basal ganglia hemorrhage, especially in patients with a hematoma volume ≥40 mL.

影响因子:0.96
发表时间:2020-02-01
DOI:10.1002/jcu.22762
作者列表:["Meng L","Zhao D","Yang Z","Wang B"]

METHODS:OBJECTIVE:The primary purpose of this study was to evaluate the effectiveness of a three-dimensional (3D) software tool (smart planes) for displaying fetal brain planes, and the secondary purpose was to evaluate its accuracy in performing automatic measurements. MATERIAL AND METHODS:This prospective study included singleton fetuses with a gestational age (GA) greater than 18 weeks. Transabdominal two-dimensional ultrasound (2DUS) and 3D smart planes images were respectively used to obtain the basic planes of the fetal brain, with five parameters measured. The images, by either two-dimensional (2D) manual or 3D automatic operation, were reviewed by two experienced sonographers. The agreements between two measurements were analyzed. RESULTS:A total of 226 cases were included. The rates of successful detection by automatic display were as high as 80%. There was substantial agreement between the measurements of the biparietal diameter, head circumference and transcerebellar diameter, but poor agreement between the measurements of cisterna magna and lateral ventricle width. CONCLUSIONS:Smart Planes might be valuable for the rapid evaluation of fetal brain, because it simplifies the evaluation process. However, the technology requires improvement. In addition, this technology cannot replace the conventional manual US scans; it can only be used as an additional approach.

翻译标题与摘要 下载文献
三维成像方向

用电子、摄影或其他方法产生三维图像的过程。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: