小狗阅读会员会员
医学顶刊SCI精读工具

扫码登录小狗阅读

阅读SCI医学文献
Document
订阅泛读方向 订阅泛读期刊
  • 我的关注
  • 我的关注
  • {{item.title}}

    按需关注领域/方向,精准获取前沿热点

  • {{item.title}}

    {{item.follow}}人关注

  • {{item.subscribe_count}}人订阅

    IF:{{item.impact_factor}}

    {{item.title}}

Body shape: Implications in the study of obesity and related traits.

身体形状: 肥胖和相关性状研究的意义。

  • 影响因子:1.64
  • DOI:10.1002/ajhb.23323
  • 作者列表:"Navarro P","Ramallo V","Cintas C","Ruderman A","de Azevedo S","Paschetta C","Pérez O","Pazos B","Delrieux C","González-José R
  • 发表时间:2020-03-01
Abstract

OBJECTIVES:The diagnosis and treatment of obesity are usually based on traditional anthropometric variables including weight, height, and several body perimeters. Here we present a three-dimensional (3D) image-based computational approach aimed to capture the distribution of abdominal adipose tissue as an aspect of shape rather than a relationship among classical anthropometric measures. METHODS:A morphometric approach based on landmarks and semilandmarks placed upon the 3D torso surface was performed in order to quantify abdominal adiposity shape variation and its relation to classical indices. Specifically, we analyzed sets of body cross-sectional circumferences, collectively defining each, along with anthropometric data taken on 112 volunteers. Principal Component Analysis (PCA) was performed on 250 circumferences located along the abdominal region of each volunteer. An analysis of covariance model was used to compare shape variables (PCs) against anthropometric data (weight, height, and waist and hip circumferences). RESULTS:The observed shape patterns were mainly related to nutritional status, followed by sexual dimorphism. PC1 (12.5%) and PC2 (7.5%) represented 20% of the total variation. In PCAs calculated independently by sex, linear regression analyses provide statistically significant associations between PC1 and the three classical indexes: body mass index, waist-to-height ratio, and waist-hip ratio. CONCLUSION:Shape indicators predict well the behavior of classical markers, but also evaluate 3D and geometric features with more accuracy as related to the body shape under study. This approach also facilitates diagnosis and follow-up of therapies by using accessible 3D technology.

摘要

目的: 肥胖的诊断和治疗通常基于传统的人体测量变量,包括体重,身高和几个身体周长。在这里,我们提出了一种基于三维 (3D) 图像的计算方法,旨在捕捉腹部脂肪组织的分布作为形状的一个方面,而不是经典人体测量之间的关系。 方法: 为了量化腹部肥胖的形状变化及其与经典指数的关系,进行了一种基于放置在3D躯干表面上的标志和半标记的形态测量方法。具体来说,我们分析了身体横截面周长的集合,共同定义了每一个,以及112名志愿者的人体测量数据。对位于每个志愿者的腹部区域的250个圆周进行主成分分析 (PCA)。协方差模型分析用于比较形状变量 (PCs) 与人体测量数据 (体重,身高,腰围和臀围)。 结果: 观察到的形态类型主要与营养状况有关,其次是性别二态性。PC1 (12.5%) 和PC2 (7.5%) 代表总变异的20%。在按性别独立计算的PCAs中,线性回归分析提供了PC1与三种经典指标 (体重指数、腰围身高比和腰臀比) 之间的统计学显著关联。 结论: 形状指标可以很好地预测经典标志物的行为,但也可以更准确地评估与研究中的身体形状相关的3D和几何特征。该方法还通过使用可访问的3D技术促进治疗的诊断和随访。

关键词:
阅读人数:5人
下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:4.08
发表时间:2020-01-01
来源期刊:European radiology
DOI:10.1007/s00330-019-06319-0
作者列表:["Delattre BMA","Boudabbous S","Hansen C","Neroladaki A","Hachulla AL","Vargas MI"]

METHODS:OBJECTIVES:The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS:CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS:No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS:The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS:• Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.

翻译标题与摘要 下载文献
影响因子:2.98
发表时间:2020-01-01
DOI:10.1136/neurintsurg-2019-014962
作者列表:["Guo W","Liu H","Tan Z","Zhang X","Gao J","Zhang L","Guo H","Bai H","Cui W","Liu X","Wu X","Luo J","Qu Y"]

METHODS:BACKGROUND:The main surgical techniques for spontaneous basal ganglia hemorrhage include stereotactic aspiration, endoscopic aspiration, and craniotomy. However, credible evidence is still needed to validate the effect of these techniques. OBJECTIVE:To explore the long-term outcomes of the three surgical techniques in the treatment of spontaneous basal ganglia hemorrhage. METHODS:Five hundred and sixteen patients with spontaneous basal ganglia hemorrhage who received stereotactic aspiration, endoscopic aspiration, or craniotomy were reviewed retrospectively. Six-month mortality and the modified Rankin Scale score were the primary and secondary outcomes, respectively. A multivariate logistic regression model was used to assess the effects of different surgical techniques on patient outcomes. RESULTS:For the entire cohort, the 6-month mortality in the endoscopic aspiration group was significantly lower than that in the stereotactic aspiration group (odds ratio (OR) 4.280, 95% CI 2.186 to 8.380); the 6-month mortality in the endoscopic aspiration group was lower than that in the craniotomy group, but the difference was not significant (OR=1.930, 95% CI 0.835 to 4.465). A further subgroup analysis was stratified by hematoma volume. The mortality in the endoscopic aspiration group was significantly lower than in the stereotactic aspiration group in the medium (≥40-<80 mL) (OR=2.438, 95% CI 1.101 to 5.402) and large hematoma subgroup (≥80 mL) (OR=66.532, 95% CI 6.345 to 697.675). Compared with the endoscopic aspiration group, a trend towards increased mortality was observed in the large hematoma subgroup of the craniotomy group (OR=8.721, 95% CI 0.933 to 81.551). CONCLUSION:Endoscopic aspiration can decrease the 6-month mortality of spontaneous basal ganglia hemorrhage, especially in patients with a hematoma volume ≥40 mL.

影响因子:0.96
发表时间:2020-02-01
DOI:10.1002/jcu.22762
作者列表:["Meng L","Zhao D","Yang Z","Wang B"]

METHODS:OBJECTIVE:The primary purpose of this study was to evaluate the effectiveness of a three-dimensional (3D) software tool (smart planes) for displaying fetal brain planes, and the secondary purpose was to evaluate its accuracy in performing automatic measurements. MATERIAL AND METHODS:This prospective study included singleton fetuses with a gestational age (GA) greater than 18 weeks. Transabdominal two-dimensional ultrasound (2DUS) and 3D smart planes images were respectively used to obtain the basic planes of the fetal brain, with five parameters measured. The images, by either two-dimensional (2D) manual or 3D automatic operation, were reviewed by two experienced sonographers. The agreements between two measurements were analyzed. RESULTS:A total of 226 cases were included. The rates of successful detection by automatic display were as high as 80%. There was substantial agreement between the measurements of the biparietal diameter, head circumference and transcerebellar diameter, but poor agreement between the measurements of cisterna magna and lateral ventricle width. CONCLUSIONS:Smart Planes might be valuable for the rapid evaluation of fetal brain, because it simplifies the evaluation process. However, the technology requires improvement. In addition, this technology cannot replace the conventional manual US scans; it can only be used as an additional approach.

翻译标题与摘要 下载文献
三维成像方向

用电子、摄影或其他方法产生三维图像的过程。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

科研福利

临床科研之家订阅号

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: