Epicardial left atrial appendage occlusion with a new medical device: assessment of procedural feasibility, safety and efficacy in a large animal model

心外膜左心耳封堵术与新型医疗器械: 大型动物模型的手术可行性、安全性和有效性评估

  • 影响因子:1.39
  • DOI:10.1186/s13019-020-01096-0
  • 作者列表:"Maximilian Y. Emmert","Michael S. Firstenberg","Arthur T. Martella","Liming Lau","Stephen Zlock","Ashik Mohan","Taylor Spangler","Sarah Currie","Sacha P. Salzberg","Etem Caliskan
  • 发表时间:2020-04-03
Abstract

Abstract Background Left atrial appendage occlusion (LAAO) represents a treatment alternative to anticoagulation in patients with atrial fibrillation. We evaluate a novel device for epicardial LAAO in a translational canine model. Methods Nine hounds (n = 9) were used to assess usability, safety, and efficacy of the TigerPaw Pro (TPP) device for epicardial LAAO. Following baseline imaging (intra-cardiac echocardiography (ICE) and angiography) and intraoperative visual inspection, usability was tested via a ``closure/re-opening`` maneuver followed by deployment of a total of twenty TPP devices (n = 20) on the left and right atrial appendages respectively. Procedural safety was evaluated by assessing for adverse-events via direct Epicardial inspection and endocardial imaging. Efficacy evaluation included assessment of device positioning, presence of residual stumps and completeness of closure. Post-mortem evaluation was performed to confirm safety and efficacy. Results Usability testing of all TPP devices was successful (n = 20;100%, delivery-time range 22–120 s) without any procedural adverse-events (tissue damage or tears, bleeding, vessel-impingement, structural impact). All devices fully traversed the ostium (n = 18) or appendage body (n = 2), and conformed smoothly to adjacent cardiac anatomy. In nineteen deployments (n = 19;95%), all device connector pairs were fully engaged, while in one TPP device the most distal pair remained unengaged. ICE and post-mortem inspections revealed complete closure of all appendage ostia (n = 18;100%) and only in one case a small residual stump was detected. Intraoperative safety findings were further confirmed post-mortem. Devices created a nearly smooth line of closure via symmetric endocardial tissue-coaptation. Conclusions In this preclinical model, the TPP demonstrated good ease of use for ostial access, ability to re-position (after engagement) and rapid deployment, while achieving safe and effective LAAO.

摘要

摘要背景: 左心耳封堵术 (LAAO) 代表了心房颤动患者抗凝治疗的替代方法。我们在翻译犬模型中评价了一种新的心外膜 LAAO 装置。方法使用 9 只猎犬 (n = 9) 评估 TigerPaw Pro (TPP) 器械用于心外膜 LAAO 的可用性、安全性和有效性。在基线成像 (心内超声心动图 (ICE) 和血管造影) 和术中视觉检查之后,通过 “闭合/再开放” 手法测试可用性,随后分别在左心耳和右心耳上部署共 20 个 TPP 装置 (n = 20)。通过直接心外膜检查和心内膜成像评估不良事件来评价手术安全性。疗效评价包括评估器械定位、残留残肢的存在和闭合的完整性。进行死后评估以确认安全性和有效性。结果所有 TPP 器械的可用性测试均成功 (n = 20;100%,递送时间范围 22-120 s),无任何程序性不良事件 (组织损伤或撕裂、出血、血管冲击,结构冲击)。所有器械完全穿过开口 (n = 18) 或附件体 (n = 2),并顺利符合邻近心脏解剖结构。在 19 个部署中 (n = 19;95%),所有设备连接器对均完全接合,而在一个 TPP 设备中,最远端对保持未接合。冰和死后检查发现所有附件开口完全闭合 (n = 18;100%),仅在 1 例病例中检测到小残留残端。术中安全检查结果在尸检后进一步证实。器械通过对称的心内膜组织连接创造了一条近乎平滑的闭合线。结论在这个临床前模型中,TPP 表现出了良好的开口访问易用性、重新定位 (接合后) 和快速部署的能力,同时实现了安全有效的 LAAO。

下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:3.75
发表时间:2020-01-01
DOI:10.1093/europace/euz244
作者列表:["Berte B","Hilfiker G","Moccetti F","Schefer T","Weberndörfer V","Cuculi F","Toggweiler S","Ruschitzka F","Kobza R"]

METHODS:AIMS:Pulmonary vein isolation (PVI) using ablation index (AI) incorporates stability, contact force (CF), time, and power. The CLOSE protocol combines AI and ≤6 mm interlesion distance. Safety concerns are raised about surround flow ablation catheters (STSF). To compare safety and effectiveness of an atrial fibrillation (AF) ablation strategy using AI vs. CLOSE protocol using STSF.,METHODS AND RESULTS:First cluster was treated using AI and second cluster using CLOSE. Procedural data, safety, and recurrence of any atrial tachycardia (AT) or AF >30 s were collected prospectively. All Classes 1c and III anti-arrhythmic drugs (AAD) were stopped after the blanking period. In total, all 215 consecutive patients [AI: 121 (paroxysmal: n = 97), CLOSE: n = 94 (paroxysmal: n = 74)] were included. Pulmonary vein isolation was reached in all in similar procedure duration (CLOSE: 107 ± 25 vs. AI: 102 ± 24 min; P = 0.1) and similar radiofrequency time (CLOSE: 36 ± 11 vs. AI: 37 ± 8 min; P = 0.4) but first pass isolation was higher in CLOSE vs. AI [left veins: 90% vs. 80%; P < 0.05 and right veins: 84% vs. 73%; P < 0.05]. Twelve-month off-AAD freedom of AF/AT was higher in CLOSE vs. AI [79% (paroxysmal: 85%) vs. 64% (paroxysmal: 68%); P < 0.05]. Only four patients (2%) without recurrence were on AAD during follow-up. Major complications were similar (CLOSE: 2.1% vs. AI: 2.5%; P = 0.87).,CONCLUSION:The CLOSE protocol is more effective than a PVI approach solely using AI, especially in paroxysmal AF. In this off-AAD study, 79% of patients were free from AF/AT during 12-month follow-up. The STSF catheter appears to be safe using conventional CLOSE targets.

翻译标题与摘要 下载文献
影响因子:2.45
发表时间:2020-01-01
DOI:10.1111/jce.14268
作者列表:["Qin M","Jiang WF","Wu SH","Xu K","Liu X"]

METHODS:OBJECTIVE:To investigate the role of driver mechanism and the effect of electrogram dispersion-guided driver mapping and ablation in atrial fibrillation (AF) at different stages of progression.,METHODS:A total of 256 consecutive patients with AF who had undergone pulmonary vein isolation (PVI) plus driver ablation or conventional ablation were divided into three groups: paroxysmal atrial fibrillation (PAF; group A, n = 51); persistent atrial fibrillation (PsAF; group B, n = 38); and long standing-persistent atrial fibrillation (LS-PsAF; group C, n = 39). PVI was performed with the guidance of the ablation index. The electrogram dispersion was analyzed for driver mapping.,RESULTS:The most prominent driver regions were at roof (28.0%), posterior wall (17.6%), and bottom (21.3%). From patients with PAF to those with PsAF and LS-PsAF: the complexity of extra-pulmonary vein (PV) drivers including distribution, mean number, and area of dispersion region increased (P < .001). Patients who underwent driver ablation vs conventional ablation had higher procedural AF termination rate (76.6% vs 28.1%; P < .001). With AF progression, the termination rate gradually decreased from group A to group C, and the role of PVI in AF termination was also gradually weakened from group A to group C (39.6%, 7.4%, and 4.3%; P < .001) in patients with driver ablation. At the end of the follow-up, the rate of sinus rhythm maintenance was higher in patients with driver ablation than those with conventional ablation (89.1% vs 70.3%; P < .001).,CONCLUSION:The formation of extra-PV drivers provides an important mechanism for AF maintenance with their complexity increasing with AF progression. Electrogram dispersion-guided driver ablation appears to be an efficient adjunctive approach to PVI for AF treatment.

翻译标题与摘要 下载文献
影响因子:1.65
发表时间:2020-01-06
DOI:10.1007/s10840-019-00700-1
作者列表:["Takamiya T","Nitta J","Inaba O","Sato A","Ikenouchi T","Murata K","Inamura Y","Takahashi Y","Goya M","Hirao K"]

METHODS:PURPOSE:Whether or not pulmonary vein isolation (PVI) plus left atrial posterior wall isolation (PWI) using contact force (CF) sensing improves the ablation outcome for persistent atrial fibrillation (AF) is unclear. This study compared the outcome of PVI plus PWI and additional non-PV trigger ablation for persistent AF with/without CF sensing. METHODS:This retrospective cohort study analyzed 148 propensity score-matched persistent AF patients (median duration of persistent AF, 8 months (interquartile range, 3-24 months); left atrial diameter, 43 ± 7 mm) undergoing PVI plus PWI and ablation of non-PV triggers provoked by high-dose isoproterenol, including 74 with CF-sensing catheters (CF group) and 74 with conventional catheters (non-CF group). PVI plus PWI with no additional ablation but cavotricuspid isthmus ablation was performed without non-PV triggers in 48 CF patients (65%) and 54 non-CF patients (73%) (P = 0.38). In all other patients, we performed additional ablation of provoked non-PV triggers. RESULTS:The Kaplan-Meier estimate of the rate of freedom from atrial tachyarrhythmia recurrence of antiarrhythmic drugs at 12 months after the single procedure was higher in the CF group than in the non-CF group (85 vs. 70%, log-rank P = 0.030). A multivariable analysis revealed that using CF sensing and non-inducibility of AF from a non-PV trigger after PVI and PWI were significantly associated with a reduced rate of atrial tachyarrhythmia recurrence. CONCLUSIONS:Compared with non-CF sensing, PVI plus PWI and additional non-PV trigger ablation using CF-sensing catheters for persistent AF can reduce the rate of atrial tachyarrhythmia recurrence.

翻译标题与摘要 下载文献
方向

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

科研福利

临床科研之家订阅号

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: