小狗阅读会员会员
医学顶刊SCI精读工具

扫码登录小狗阅读

阅读SCI医学文献
Document
订阅泛读方向 订阅泛读期刊
  • 我的关注
  • 我的关注
  • {{item.title}}

    按需关注领域/方向,精准获取前沿热点

  • {{item.title}}

    {{item.follow}}人关注

  • {{item.subscribe_count}}人订阅

    IF:{{item.impact_factor}}

    {{item.title}}

Incidentally detected focal fundal gallbladder wall thickening: Differentiation contrast enhanced ultrasound features with high-resolution linear transducers.

偶然检测到局灶性胆囊壁增厚: 高分辨率线性换能器的鉴别超声造影特征。

  • 影响因子:1.33
  • DOI:10.3233/CH-190697
  • 作者列表:"Dong Y","Xu B","Cao Q","Zhang Q","Qiu Y","Yang D","Yu L","Wang WP
  • 发表时间:2020-01-01
Abstract

AIM:To investigate the value of contrast enhanced ultrasound with high resolution linear transducers (HF-CEUS) for differential diagnosis of focal fundal gallbladder (GB) wall thickening. METHODS:A total of 32 patients with incidentally detected focal fundal GB wall thickening were included. After conventional B mode ultrasound (BMUS) examinations, HF-CEUS were performed with a 7.5-12 MHz 9L4 linear transducer (S2000 HELX OXANA unit, Siemens). Two radiologists independently reviewed the HF-CEUS enhancement patterns to determine the differential features between malignancy and benignity with a five-point confidence scale. The diagnostic accuracy of BMUS and HF-CEUS for GB wall thickening was compared. The final gold standard was surgery with histological examination. RESULTS:Final diagnoses included GB adenocarcinoma (n = 16), adenomyomatosis (n = 12), Xanthogranulomatous (n = 2) and cholecystitis (n = 2). HF-CEUS features associated with GB adenocarcinoma including arterial phase inhomogeneous hyperenhancement, venous phase hypoenhancement and disruption of GB wall layer structure (P < 0.05). Two small (5 mm) liver metastasis were confirmed by HF-CEUS during the late phase liver sweep as hypoenhanced lesions. Nonenhanced Rokitansky-Aschoff sinuses were clearly observed in 83.3% focal adenomyomatosis. Overall sensitivity, specificity and accuracy for differentiation between malignant and benign focal fundal GB wall thickening of HF-CEUS and BMUS were 84.3% vs 53.1%, 90.6% vs 59.3% and 87.5% vs 56.2% (P < 0.005). CONCLUSIONS:CEUS performed with high frequency linear transducers could be a useful alternative in the differential diagnosis of focal fundal GB wall thickening on conventional ultrasound.

摘要

目的: 探讨高分辨率线性超声造影 (HF-CEUS) 对局灶性胆囊壁增厚的鉴别诊断疾病价值。 方法: 共纳入 32 例偶然检出局灶性胃底GB壁增厚的患者。常规b型超声 (BMUS) 检查后,用 7.5-12 mhz 9L4 线性换能器 (S2000 HELX OXANA unit,Siemens) 进行HF-CEUS。两名放射科医生独立审查了HF-CEUS增强模式,以五点置信量表确定恶性和良性之间的差异特征。比较BMUS和HF-CEUS对GB管壁增厚的诊断准确性。最终的金标准是手术加组织学检查。 结果: 最终诊断包括GB腺癌 (n = 16) 、腺肌增生症 (n = 12) 、黄色肉芽肿 (n = 2) 和胆囊炎 (n = 2)。与GB腺癌相关的HF-CEUS特征包括动脉期不均匀超增强、静脉期低增强和GB壁层结构破坏 (p <0.05)。两例小 (5mm) 肝转移在晚期肝扫描时经HF-CEUS证实为低强化病灶。在 83.3% 例局灶性子宫腺肌病中清晰观察到非强化Rokitansky-Aschoff窦。HF-CEUS和BMUS鉴别恶性和良性局灶性胃底GB壁增厚的总体敏感性、特异性和准确性分别为 84.3% vs 53.1%,90.6% vs 59.3% 和 87.5% vs 56.2% (p <0.005)。 结论: 高频线性换能器超声造影可作为常规超声检查局灶性胃底增厚的鉴别诊断疾病。

下载该文献
小狗阅读

帮助医生、学生、科研工作者解决SCI文献找不到、看不懂、阅读效率低的问题。提供领域精准的SCI文献,通过多角度解析提高文献阅读效率,从而使用户获得有价值研究思路。

相关文献
影响因子:1.33
发表时间:2020-01-01
DOI:10.3233/CH-190697
作者列表:["Dong Y","Xu B","Cao Q","Zhang Q","Qiu Y","Yang D","Yu L","Wang WP"]

METHODS:AIM:To investigate the value of contrast enhanced ultrasound with high resolution linear transducers (HF-CEUS) for differential diagnosis of focal fundal gallbladder (GB) wall thickening. METHODS:A total of 32 patients with incidentally detected focal fundal GB wall thickening were included. After conventional B mode ultrasound (BMUS) examinations, HF-CEUS were performed with a 7.5-12 MHz 9L4 linear transducer (S2000 HELX OXANA unit, Siemens). Two radiologists independently reviewed the HF-CEUS enhancement patterns to determine the differential features between malignancy and benignity with a five-point confidence scale. The diagnostic accuracy of BMUS and HF-CEUS for GB wall thickening was compared. The final gold standard was surgery with histological examination. RESULTS:Final diagnoses included GB adenocarcinoma (n = 16), adenomyomatosis (n = 12), Xanthogranulomatous (n = 2) and cholecystitis (n = 2). HF-CEUS features associated with GB adenocarcinoma including arterial phase inhomogeneous hyperenhancement, venous phase hypoenhancement and disruption of GB wall layer structure (P < 0.05). Two small (5 mm) liver metastasis were confirmed by HF-CEUS during the late phase liver sweep as hypoenhanced lesions. Nonenhanced Rokitansky-Aschoff sinuses were clearly observed in 83.3% focal adenomyomatosis. Overall sensitivity, specificity and accuracy for differentiation between malignant and benign focal fundal GB wall thickening of HF-CEUS and BMUS were 84.3% vs 53.1%, 90.6% vs 59.3% and 87.5% vs 56.2% (P < 0.005). CONCLUSIONS:CEUS performed with high frequency linear transducers could be a useful alternative in the differential diagnosis of focal fundal GB wall thickening on conventional ultrasound.

翻译标题与摘要 下载文献
影响因子:1.79
发表时间:2020-01-01
来源期刊:Surgery today
DOI:10.1007/s00595-019-01881-y
作者列表:["Yoshizumi T","Mori M"]

METHODS::Small-for-size graft (SFSG) syndrome after living donor liver transplantation (LDLT) is the dysfunction of a small graft, characterized by coagulopathy, cholestasis, ascites, and encephalopathy. It is a serious complication of LDLT and usually triggered by excessive portal flow transmitted to the allograft in the postperfusion setting, resulting in sinusoidal congestion and hemorrhage. Portal overflow injures the liver directly through nutrient excess, endothelial activation, and sinusoidal shear stress, and indirectly through arterial vasoconstriction. These conditions may be attenuated with portal flow modulation. Attempts have been made to control excessive portal flow to the SFSG, including simultaneous splenectomy, splenic artery ligation, hemi-portocaval shunt, and pharmacological manipulation, with positive outcomes. Currently, a donor liver is considered a SFSG when the graft-to-recipient weight ratio is less than 0.8 or the ratio of the graft volume to the standard liver volume is less than 40%. A strategy for transplanting SFSG safely into recipients and avoiding extensive surgery in the living donor could effectively address the donor shortage. We review the literature and assess our current knowledge of and strategies for portal flow modulation in LDLT.

翻译标题与摘要 下载文献
影响因子:2.01
发表时间:2020-02-01
DOI:10.1016/j.jss.2019.08.025
作者列表:["Khan MS","Shahzad N","Arshad S","Shariff AH"]

METHODS:BACKGROUND:Seasonal variation in the occurrence of medical illnesses reflects the effect of the environment, provides insight into pathogenesis, and can assist health care administrators in allocating resources accordingly. Seasonal variation has been reported in various infectious and surgical diseases, but has been rarely studied in acute cholecystitis. Our objective was to study seasonal variation in acute cholecystitis at our institution. METHODS:We performed a retrospective analysis of patients who underwent cholecystectomy for acute cholecystitis from January 1988 to December 2018. Chi-square goodness-of-fit test was used to analyze seasonality of acute cholecystitis adjusting for variation in number of days between seasons. The number of days for seasons were taken as 92, 92, 91, and 90.25 for spring, summer, fall, and winter, respectively. RESULTS:Overall, 3924 patients underwent cholecystectomy for acute cholecystitis during the study period. The frequency of cholecystectomies performed varied between months (minimum February n = 259, maximum July n = 372, P < 0.001) and seasons (minimum winter n = 789, maximum summer n = 1101 P < 0.001). Age and gender distribution across months and seasons was similar (P > 0.05). CONCLUSIONS:Our findings confirm seasonal variation in occurrence of acute cholecystitis with summer season witnessing the most and the winter season encountering the least patients with acute cholecystitis. Validation of our findings through prospectively collected data at national level is the way forward.

关键词: 暂无
翻译标题与摘要 下载文献
胆道疾病方向

胆道疾病指发生于胆道系统的疾病。临床上常见的胆道疾病包括结石、肿瘤、寄生虫病、先天性畸形等。胆道的病变可造成胆道梗阻使胆汁淤滞,进一步影响肝脏功能,且常导致继发感染,胆道结石等慢性刺激也可诱发恶性肿瘤。

复制标题
发送后即可在该邮箱或我的下载查看该文献
发送
该文献默认存储到我的下载

科研福利

临床科研之家订阅号

报名咨询

建议反馈
问题标题:
联系方式:
电子邮件:
您的需求: